Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer |
Output Type: | Triple |
Still deciding? Get samples of US$ 120/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Controller Model | Power Capacity (kVA) | Input Current (A) | Output Current (A) | Rated Power (kW) |
Three phase 220V (range of 220V to 240V 50/60Hz) | ||||
LX5000-3R7G-2 | 6.9 | 17 | 14 | 3.7 |
LX5000-5R5G-2 | 10.2 | 29 | 27 | 5.5 |
LX5000-7R5G-2 | 13.5 | 36 | 33 | 7.5 |
Three phase 380V (range of 380V to 440V 50/60Hz) | ||||
LX5000-3R7G-4 | 8.0 | 10.5 | 9.0 | 3.7 |
LX5000-5R5G-4 | 11.5 | 14.8 | 13 | 5.5 |
LX5000-7R5G-4 | 15 | 20.5 | 18 | 7.5 |
LX-5000-011G-4 | 22 | 29 | 27 | 11 |
LX-5000-015G-4 | 29.7 | 36 | 33 | 15 |
Item
|
Specification
|
|
Input power supply |
Number of phases,
voltage, and frequency
|
200 V class: Single-phase 180 VAC to 240 VAC, 50 Hz/60 Hz 380 V class: Three-phase 330 VAC to 440 VAC, 50 Hz/60 HzAllowable voltage change |
Allowable voltage change
|
-15% to +10% | |
Allowable frequency change
|
-5% to +5% | |
Capacity to withstand instantaneous voltage drop
|
200 V class: The system continues to run at over 150 VAC. When the voltage is reduced to below 150 VAC from the rated input state, undervoltage protection is enabled after the system continues to run for 15 ms. 400 V class: The system continues to run at over 300 VAC. When the voltage is reduced to below 300 VAC from the rated input state, undervoltage protection is enabled after the system continues to run for 15 ms. |
|
Basic features | Communication mode | CANbus and RS485 serial communication |
Drive features
|
Control mode
|
Vector control with a PG card |
Starting torque
|
Up to 200% rated torque, depending on the load | |
Speed control range | 1:1000 (Vector control with a PG card) | |
Speed control accuracy | ±0.05% (Vector control with a PG card, 25±10ºC) | |
Torque limit | 200% rated torque | |
Torque accuracy | ±5% | |
Frequency control range | 0 Hz to 99 Hz | |
Frequency accuracy | ±0.1% | |
Resolution of frequency setting | 0.01 Hz/99 Hz | |
Output frequency resolution (Calculated resolution) | 0.01 Hz | |
No- load startup compensation |
In the event that the elevator load size is unknown, an appropriate torque is applied to the motor according to the elevator running direction, achieving smooth startup, minimizing rollback at the moment of startup and improving the riding comfort.
|
|
Braking torque | 150% rated torque (external braking resistor), built-in braking unit | |
Acceleration/Deceleration time |
0.1s to 8s
|
|
Carrier frequency |
2 kHz to 16 kHz
|
|
Battery running | Upon power failure, the elevator performs leveling at the nearest floor at a low speed using power supply from the battery. | |
PG port
|
PG card types
|
Open collector, push-pull differential type, sin/cos, and absolute encoder (Heidenhain 1313/413, Weton EA53)
|
Frequency-division output of PG card signal
|
OA orthogonal to OB
|
|
I/O signal
|
Photocoupler input control power supply
|
Isolated 24 VDC
|
Low voltage photocoupler isolation input
|
24-channel DI. Photocoupler control signals are isolated 24 VDC power input signals.
|
|
High voltage photocoupler isolation input
|
4-channel DI
|
|
Relay outputs
|
6-channel NO contacts, single pole single throw, 5 A contact switchover capability, contact load (Resistive) of 5 A/250 VAC or 5 A/28 VDC
|
|
USB port | Commissioning using the mobile phone | |
CAN communication port | 2 channels (Car top communication, parallel or group control) | |
Modbus communication | 2 channels (Landing call communication, elevator monitoring B0S or IoT) | |
Analog input (AI)
|
1 single-ended or differential input, input voltage range -10 V to +10 V, precision 0.1%
|
|
Protection features | Motor overload protection | A motor protection curve can be set |
AC drive overload | 60s for 150% of the rated current, 10s for 200% of the rated current | |
Short circuit protection | The drive controller is protected when any ttttttttt short circuit on the output side causes overcurrent. | |
Phase loss protection | The AC drive provides the phase loss detection function. In case of incorrect input phase sequence, the control system will report phase loss and stop the elevator to prevent accidents. | |
Bus overvoltage threshold | Bus voltage 800 V (for 380 V series) and 400 V (for 220 V series) | |
Bus undervoltage threshold | Bus voltage 350 V (for 200 V series) and 150 V (for 220 V series) | |
Compensation due to instantaneous power failure | For instantaneous power failure time above 15 ms | |
Heatsink overheat | Protected by the thermistor | |
Stall prevention | Stall protection is enabled when the speed deviation is greater than 15% of the rated speed during running | |
Rotary encoder abnormality | The system performs protection immediately to prevent accidents when any of the following rotary encoder malfunctions occurs: phase loss, reverse direction, disconnection, and pulse interference. | |
Braking unit protection | The braking unit is protected when malfunction is automatically detected. | |
Module protection | Overcurrent, short circuit and overheat protection | |
Current sensor protection | Self-test at power-on | |
Speed abnormality protection | When the encoder feedback speed exceeds the limit or the deviation between the torque limit and the feedback speed is too large, the system will immediately perform protection, generate an alarm, and prohibit running, achieving quick protection against abnormal elevator speed. | |
Output grounding protection | When any phase is short-circuited to ground during running, output is cut off to protect the controller. | |
Output imbalance protection | When three- phased current output imbalance is detected during running, output is cut off to protect the controller. | |
Braking resistor short circuit protection | Detection during braking | |
Running time limiter protection | Protection is enabled if the time for moving through a floor exceeds the specified time during running. | |
Leveling switch abnormality protection | Leveling switches are malfunctioned when they fail and are stuck. The system judges the malfunction type according to the change of leveling signal feedback. If the leveling signals have no change in the set time, the system will generate an alarm. | |
EEPROM fault | Self-test at power-on | |
Display
|
Keypad | 3-digit LED display, implementing certain commissioning functions |
Operating panel |
5-digit LED display, enabling the query and modification of most parameters and the monitoring of system state
|
|
Commissioning using mobile phone app
|
Connect the system with the mobile phone app to view and modify the system state | |
Environment
|
Temperature | -10ºC to 50ºC (de-rated if the ambient temperature is above 40°C) |
Humidity |
Less than 95% RH, non-condensing
|
|
Vibration |
< 5.9 m/s 2 (0.6 g)
|
|
Storage temperature | -20ºC to 60ºC (short-term temperature in transit) | |
Operating site |
Indoor use (No corrosive gases or dust)
|
|
Pollution degree
|
PD2
|
|
IP rating | IP20 | |
Power distribution system | TN/TT | |
Altitude | 1000 m or below (de-rated by 1% for each 100 m higher if the altitude is above 1000 m) | |
Structure |
Degree of protection
|
IP20 |
Cooling mode | Forced air cooling | |
Installation method | Cabinet assembly |
Haiyan Lixiang Electronic Technology Co., Ltd. and its affiliated company Zhejiang Qibin Technology Co., Ltd. are located in Haiyan City, enjoying convenient transportation. We are a professional manufacturer of frequency inverters, integrating R&D, production and sales. We have a modern plant area of more than 26,794 square meters, with international manufacturing and testing equipment, intelligent laboratory. We also own excellent teams who focus on product development and design, quality control and inspection and company running. Our products are certificated by I S O 9 0 0 1, C E and S G S etc. The main products, solar pumping variable frequency drives, elevator drives, universal inverters and related products are widely used in steel, building materials, textile, printing and machine tool industries, etc. Besides, we are making great efforts to develop new products to meet different requirements. If you have any new ideas for the products, please contact us. We are glad to bring you the satisfied products. With decades of experience in the frequency inverters industry, our products are selling well around China. Furthermore, we have created partnerships with thousands of customers worldwide such as Southeast Asia, Middle East, Europe, the U S and other areas. Adhering to the principle of mutual benefits, we have had a reliable reputation among our customers because of our professional services, quality products and competitive prices. We warmly welcome customers from at home and abroad to cooperate with us for common success. |